4 Relay Modbus RTU Module RS485

:MRE03039
€15.90
Tax included

Multi-unit network 485 communication, based on MODBUS-RTU protocol, the default communication address is 1, users can modify the address by instructions.

Quantity
Last items in stock

If you have any questions on this product please feel free to contact us.

*Disclaimer: The images are merely illustrative.

Relay voltage: power supply 12V.

Relay communication: Multi-unit network 485 communication, based on MODBUS-RTU protocol, the default communication address is 1, users can modify the address by instructions

IN1-IN4 are connected to the switch. The switch status is read through 485, not through the input control relay output.

Note: IN1-IN4 cannot be connected to 230Vac (some buyers will make this mistake)

 

Layout

The wiring is as follows:

IN1-GND (default is high level, low level after the switch is turned on) The computer sends instructions to read the switch status.

IN2-GND (default is high level, low level after the switch is turned on) The computer sends instructions to read the switch status.

IN3-GND (default is high level, low level after the switch is turned on) the computer sends instructions to read the switch status.

IN4-GND (default is high level, low level after the switch is turned on) The computer sends instructions to read the switch status.

Command function:

1. Set the address to 

2. Read the address 

3. Read the software version 

4. Read the hardware version

MODBUS-RTU communication instruction:

Function code: 05 is the relay output [control relay on/off]

Function code: 06 is stored data [user-defined storage data, user-defined data, address number, set by the user. Generally useless]

/**********************************************************************/

Modbus RTU instruction

Baud rate: 9600 8 NONE 1

Send in hexadecimal

Hexadecimal reception

Steps: 

1. The software sets the communication baud rate

2. Set the address (device address used for communication)

The instruction with address 1 set by default

/************************************************* ******************/

Set the address as: 01

Send: 00 06 40 00 00 01 5c 1b

Return: 01 06 00 00 00 01 48 0A

Set the address as: 02

Send: 00 06 40 00 00 02 1c 1a

Return: 02 06 00 00 00 02 08 38

Read address

00 03 40 00 00 01 90 1b

/************************************************* ******************/

Read software version

Send: 00 03 00 02 00 01 24 1b //【Sun】

Return: 01 03 02 10 00 B5 84 //No. 10

Send: 00 03 00 04 00 01 c4 1a //[month] Broadcast reading (only one device can be connected, practical for all addresses, convenient for testing)

Return: 01 03 02 4D 61 4C FC //4D[M] 61[A] MAR[March]

Send: 00 03 00 08 00 01 04 19 //【year】 Broadcast reading (only one device can be connected, practical for all addresses, convenient for testing)

Returns: 01 03 02 20 18 A1 8E //20 18 = 2018

Send: 00 03 00 10 00 01 84 1e //[Hour, Minute] //Broadcast reading (only one device can be connected, practical for all addresses, convenient for testing)

Return: 01 03 02 21 26 21 CE //21:26

Read hardware version (PCB version)

Send: 00 03 00 20 00 01 84 11 //Broadcast reading (only one device can be connected, practical for all addresses, convenient for testing)

Return: 01 03 02 00 6A 38 6B //6A = 106 =V1.06

Send: 01 03 00 20 00 01 85 c0

Return: 01 03 02 00 6A 38 6B //6A = 106 =V1.06

/************************************************* ******************/

[Address 1]

//--------------------------------------------

Relay 0 turns on: 01 05 00 00 FF 00 8C 3A

Relay 0 is off: 01 05 00 00 00 00 CD CA

//--------------------------------------------

Relay No. 1 turned on: 01 05 00 01 FF 00 DD FA

Relay No. 1 is closed: 01 05 00 01 00 00 9C 0A

//-------------------------------------------

Relay No. 2 turned on: 01 05 00 02 FF 00 2D FA

Relay No. 2 is off: 01 05 00 02 00 00 6C 0A

//-------------------------------------------

Relay No. 3 turned on: 01 05 00 03 FF 00 7C 3A

Relay No. 3 is closed: 01 05 00 03 00 00 3D CA

Single flip instruction:

No. 0 relay flip: 01 05 00 00 55 00 F2 9A

No. 1 relay flip: 01 05 00 01 55 00 A3 5A

No. 2 relay flip: 01 05 00 02 55 00 53 5A

No. 3 relay flip: 01 05 00 03 55 00 02 9A

Fully closed: 01 05 00 ff 00 00 fd fa

Fully open: 01 05 00 ff ff ff fc 4a

Full flip: 01 05 00 ff 5a 00 c7 5a

/************************************************* *********************/

Read relay status 0: 01 01 00 00 00 01 FD CA

Read the status of relay No. 1: 01 01 00 01 00 01 AC 0A

Read the status of relay No. 2: 01 01 00 02 00 01 5C 0A

Read the status of relay No. 3: 01 01 00 03 00 01 0D CA

Relay No.1 Read all channel status: 01 01 00 FF 00 00 3d c9

/************************************************* ********************/

Read all interface input status

01 02 00 00 00 00 78 0a

return:

01 02 01 01 60 48 //IN1 press

01 02 01 02 20 49 //IN2 press

01 02 01 04 A0 4B //IN3 press

01 02 01 08 A0 4E //IN4 press

MRE03039